certko — Compliance. Assured.

Chemical Testing

Fire-resistance tests: Part 2 Lift landing door assemblies — IS 17518: Part 2 (2021) Testing

IS 17518: Part 2 (2021) is a BIS product testing standard for cement & construction materials (1 notified product). Book laboratory testing required for ISI Mark / CRS certification.

IS · India

IS (Indian Standards) — typically accepted in India. Bureau of Indian Standards test methods — primary evidence for BIS / India market compliance and many domestic buyer specs.

Product category
Cement & Construction Materials
Main standard
IS 17518: Part 2 (2021)
Test type
Chemical / composition
Accreditation
ISO/IEC 17025 / NABL (BIS-recognised labs)
Testing timeline
7–12 working days
Sample size required
100–500 g representative sample (or as per IS)
Tentative testing price
₹5L

Indicative BIS lab charges from product records — confirm with the laboratory.

Fire-resistance tests: Part 2 Lift landing door assemblies — IS 17518: Part 2 (2021) Testing

IS 17518 (Part 2):2021 specifies fire-resistance tests for lift landing door assemblies and is identical to ISO 3008-2:2017. The standard evaluates critical fire-performance characteristics, including integrity, insulation and radiation, under specified fire exposure conditions. It helps manufacturers and suppliers demonstrate the fire-resistant performance of elevator landing doors. Certko provides testing support for products requiring evaluation as per applicable BIS standards.

BIS products tested to this standard

1 BIS-notified product map to IS 17518: Part 2 (2021) — open a product for scheme, labs and indicative costs.

FAQs about Fire-resistance tests: Part 2 Lift landing door assemblies — IS 17518: Part 2 (2021) Testing

Q1. What is the purpose of IS 17518 (Part 2):2021 testing?

IS 17518 (Part 2):2021 provides a standardized method for assessing the fire-resistance performance of lift landing door assemblies. Testing determines how the door assembly behaves under fire exposure and helps establish its ability to restrict fire and heat transmission through the lift entrance.

Q2. What is a lift landing door assembly?

A lift landing door assembly is the complete door arrangement installed at each landing of a lift or elevator shaft. It includes the door leaves and associated components necessary for operation. Under IS 17518 (Part 2):2021, the complete assembly is evaluated for its fire-resistance performance rather than considering only an individual door component.

Q3. How is IS 17518 Part 2 fire testing performed?

The lift landing door assembly is installed in a suitable fire-testing furnace and exposed to controlled fire conditions from the landing side. During the test, the assembly is monitored according to the specified procedure to determine its ability to maintain the required fire-resistance characteristics.

Q4. What is integrity in IS 17518 Part 2 testing?

Integrity refers to the ability of the lift landing door assembly to continue acting as a barrier during fire exposure. The assessment considers whether the assembly prevents the passage of flames and hot gases in accordance with the applicable test requirements.

Q5. What is insulation in lift landing door fire testing?

Thermal insulation relates to the ability of the lift landing door assembly to limit heat transfer through the door during fire exposure. Where insulation is assessed, temperature measurements are used to determine whether the assembly remains within the specified thermal performance criteria.

Q6. What is radiation testing under IS 17518 (Part 2):2021?

Radiation assessment determines the level of thermal radiation transmitted through the lift landing door assembly during fire exposure. This characteristic can be important when evaluating the potential impact of heat radiation on areas adjacent to the lift entrance.

Q7. What documents are required for IS 17518 Part 2 testing?

Typical testing projects may require product specifications, technical drawings, construction details, material information, door dimensions, installation details and relevant operating information. The exact documentation depends on the laboratory and the characteristics of the door assembly being tested.

Q8. What are the benefits of IS 17518 Part 2 testing?

Testing provides documented evidence of a lift landing door assembly's fire-resistance performance under standardized conditions. It can support product development, technical validation, customer requirements, fire-safety evaluations and compliance-related documentation for suitable applications.

Related tests in Chemical Testing

Trusted by Global Brands

Kamicka
Ang India
Albchrome
Borosil Scientific
SEAH
MapmyIndia
Toshiba
Flipkart
OPPO
Thermadyne
Alborg
Gursoygrup
Kamicka
Ang India
Albchrome
Borosil Scientific
SEAH
MapmyIndia
Toshiba
Flipkart
OPPO
Thermadyne
Alborg
Gursoygrup

Client stories

What teams say about Certko

A fresh selection of client stories each visit.

★★★★★
The lab directory alone is worth it — verified scopes and indicative pricing for hundreds of BIS labs. Our compliance team uses Certko every week.
AArvind S.Cable Exporter, Ahmedabad
★★★★★
We needed BEE star labelling and BIS CRS on the same SKU. Certko sequenced both so lab tests weren’t repeated — saved weeks and a second sample batch.
PPriya N.Electronics Brand, Bengaluru

Need a quote for Fire-resistance tests: Part 2 Lift landing door assemblies — IS 17518: Part 2 (2021) Testing?

Book this testing or share your product details. We’ll map lab scope, sample size, timeline and tentative price — update within 24 working hours.