Door Handles for Mortice Locks – Specification — IS 4992 (2024) Testing

IS 4992 (2024) is a BIS product testing standard for cement & construction materials (1 notified product). Book laboratory testing required for ISI Mark / CRS certification.

IS · India

IS (Indian Standards) — typically accepted in India. Bureau of Indian Standards test methods — primary evidence for BIS / India market compliance and many domestic buyer specs.

Product category
Cement & Construction Materials
Main standard
IS 4992 (2024)
Test type
Chemical / composition
Accreditation
ISO/IEC 17025 / NABL (BIS-recognised labs)
Testing timeline
7–12 working days
Sample size required
100–500 g representative sample (or as per IS)
Tentative testing price
₹20K

Indicative BIS lab charges from product records — confirm with the laboratory.

Door Handles for Mortice Locks – Specification — IS 4992 (2024) Testing

IS 4992:2024 specifies requirements for door handles, including lever door handles and knobs used with mortice locks. The standard covers design, dimensions, strength, durability, corrosion resistance, fire resistance, safety and operation, with a six-digit classification system. It revised IS 4992:1975 and became applicable from 14 May 2025. Certko assists manufacturers and suppliers with IS 4992:2024 testing through suitable recognised laboratories to support BIS/ISI Mark compliance.

BIS products tested to this standard

1 BIS-notified product map to IS 4992 (2024) — open a product for scheme, labs and indicative costs.

FAQs about Door Handles for Mortice Locks – Specification — IS 4992 (2024) Testing

Q1. What does IS 4992:2024 cover?

IS 4992:2024 covers door handles used for mortice locks, including lever door handles and door knobs. It specifies relevant requirements for design, construction, performance and classification to support reliable operation of mortice locks.

Q2. What types of door handles are covered under IS 4992:2024?

The standard covers lever door handles and door knobs intended for mortice locks. It also includes provisions related to handle cover plates and rosettes, helping define product designs and components within the scope of the standard.

Q3. What tests are conducted for IS 4992:2024 certification?

BIS laboratory requirements include evaluation of fastening elements and spindle, axial strength, preload, permanent deformation, safety requirements, durability testing through specified cycles, corrosion resistance and marking. Fire-resistance testing may apply according to the product classification.

Q4. Is fire resistance covered in IS 4992:2024?

Yes. Fire resistance is included in the six-digit classification system of IS 4992:2024. The applicable fire-resistance requirement depends on the classification declared for the door handle, and BIS testing scope separately identifies fire-resistance testing provisions.

Q5. What is the six-digit classification in IS 4992:2024?

IS 4992:2024 uses a six-digit coding system to classify door handles based on category of use, durability, test door mass, fire resistance, corrosion resistance and type of operation. This system helps identify the intended performance level of a product.

Q6. Does IS 4992:2024 replace IS 4992:1975?

Yes. IS 4992:2024 is the second revision of the standard and replaced IS 4992:1975. BIS issued implementation guidelines requiring transition to the revised standard, with the old standard scheduled for withdrawal after 14 May 2025.

Q7. What is the BIS certification scheme for IS 4992:2024?

The BIS Product Manual for IS 4992:2024 states that certification is operated under Scheme-I of the BIS Conformity Assessment Regulations, 2018. The manual serves as reference material for applicants, licensees and BIS offices for certification activities.

Q8. Who should obtain IS 4992:2024 testing?

Manufacturers of door handles designed for mortice locks should assess their products against IS 4992:2024 requirements where BIS certification applies. Testing helps establish conformity with applicable performance, safety, durability, corrosion and marking requirements. Certko can assist with coordinating applicable product testing.

Related tests in Chemical Testing

Trusted by Global Brands

Kamicka
Ang India
Albchrome
Borosil Scientific
SEAH
MapmyIndia
Toshiba
Flipkart
OPPO
Thermadyne
Alborg
Gursoygrup
Kamicka
Ang India
Albchrome
Borosil Scientific
SEAH
MapmyIndia
Toshiba
Flipkart
OPPO
Thermadyne
Alborg
Gursoygrup

Client stories

What teams say about Certko

A fresh selection of client stories each visit.

★★★★★
GMARK categories were confusing until Certko mapped our catalogue to the right standards matrix. Clear next steps, clear costs — we certified on the first attempt.
HHassan A.GCC Importer, Dubai
★★★★★
We needed BEE star labelling and BIS CRS on the same SKU. Certko sequenced both so lab tests weren’t repeated — saved weeks and a second sample batch.
PPriya N.Electronics Brand, Bengaluru

Need a quote for Door Handles for Mortice Locks – Specification — IS 4992 (2024) Testing?

Book this testing or share your product details. We’ll map lab scope, sample size, timeline and tentative price — update within 24 working hours.